I am an experienced Electrical Engineer with over 12 years of expertise, currently working with Aurecon as a Protection and Electrical Engineer. In this role, I contribute to major energy infrastructure projects across Australia, including battery energy storage systems (BESS), high-voltage transmission networks, and brownfield substation upgrades. My work involves protection system design, technical reviews, secondary systems design, and power system analysis to support concept development and ensure compliance with project and grid requirements.
I specialize in power system simulation and analysis, conducting detailed studies to evaluate system stability, inform design decisions, and optimize network performance. My skill set includes numerical relay testing, protection coordination studies, high-voltage equipment maintenance, and SCADA-based automation. I also bring a strong foundation in electrical design and PLC programming to support advanced control and protection schemes.
Previously, I served as a core committee member in the development of grid contingency plans for the Bhutanese power system, where I led simulation-based assessments to enhance system resilience under critical fault scenarios. I take a methodical and collaborative approach to engineering challenges and am committed to delivering robust, technically sound solutions in dynamic and complex project environments.
Atmos Merredin BESS (WA):
Serving as Electrical, Protection, and Project Engineer during the ECI phase in an Owner’s Engineer role. Managed project delivery and stakeholder engagement, successfully increasing project value from $132K to $517K through variation works.
Collie BESS (WA, for Neoen):
Operating as Protection Engineer and Principal’s Representative. Responsibilities include defining project scope, performing technical reviews of protection system designs, and witnessing Factory Acceptance Tests (FAT).
Golden Plains BESS (VIC, for TagEnergy):
Electrical Engineer for a 300MW Battery Energy Storage System. Responsible for concept design reviews and development of Balance of Plant (BOP) technical specifications and Division of Responsibility documentation.
300kV Transmission Network – Confidential Client (Pilbara Region):
Designing secondary systems and protection schemes across five substations as part of a large-scale transmission development project.
Paraburdoo Electrical Infrastructure Project (WA, for Rio Tinto Iron Ore):
Lead Engineer for the 220 kV Bulk Supply Substation. Key tasks included options assessment, concept design for brownfield substation extension, power system analysis, and generation of equipment datasheets for HV components including circuit breakers, current transformers, voltage transformers (CVT), isolators, disconnectors, and power transformers.
Electrical System Design and testing.
Planned and coordinated site works, ensuring smooth execution and timely completion of projects.
Prepared detailed daily work reports, documenting progress and highlighting any issues or challenges encountered.
Oversaw design and maintenance of control systems for generators, including excitation systems, protection systems, GIS equipment and Variable frequency drives.
Collaborated with cross-functional teams to troubleshoot and resolve technical issues related to control and protection systems.
Conducted regular inspections and audits to ensure compliance with safety standards and regulations.
Complied with planning legislation and code regulations for project implementation.
Executed staff training and quality control checks to manage engineering and administrative workforce.
Maintained and proactively developed culture of workplace health and safety resulting in excellent OSHA ENR scores.
Optimized performance of facility machinery through calibration and repairs.
Supervised, controlled, and carried out engineering and ancillary services.
Monitored and evaluated engineering performance to recommend improvements.
Electrical Design and Testing.
Successfully managed maintenance and upgrade of 6 generators, 18 transformers, and their auxiliaries, ensuring optimal performance and reliability.
Conducted insulation/thermal coordination and diagnostics for generators and transformers, identifying potential weaknesses and implementing corrective measures to prevent breakdowns and ensure equipment longevity.
Collaborated with cross-functional teams, including technicians and contractors, to execute maintenance tasks efficiently and effectively.
Monitored equipment performance and implemented necessary upgrades or repairs to optimize operational efficiency.
Conducted regular inspections and audits to ensure compliance with safety protocols and regulatory standards.
Prepared comprehensive reports documenting maintenance activities, equipment performance, and any identified issues, providing valuable insights for decision-making and future planning.
Verified construction documentation to meet client requirements and vision.
Evaluated project requirements to identify and mitigate risks.
Protection System Design.
Protection System Coordination studies for safe operation.
Conducted comprehensive testing of numerical relays of 4 power plants to ensure proper functioning of protection systems, minimizing risk of equipment failure and ensuring reliable power supply.
Assumed responsibility for troubleshooting and addressing control and protection issues that arose during generation period, ensuring minimal downtime and uninterrupted operations.
Collaborated with cross-functional teams, including technicians and contractors, to effectively resolve issues and implement necessary repairs or upgrades.
Developed and implemented preventive maintenance strategies to enhance longevity and reliability of control and protection systems.
Monitored and evaluated system performance, analyzing data, and implementing corrective measures to optimize operations.
Conducted regular inspections and audits to ensure compliance with safety regulations and industry standards.
Prepared detailed reports documenting testing results, maintenance activities, and resolutions to control and protection issues, providing valuable insights for future reference.
Adhered to timelines to meet quality assurance targets.
Participated in failure analysis and debugging report activities.
Assisted with coordination of new equipment installation and implementation.
Electrical System Design and Testing.
Protection System Design.
Provided specialized maintenance testing services to 4 power plants and 12 industries in Bhutan, ensuring optimal performance and adherence to safety standards.
Conducted simulation studies of power systems to improve system stability, identifying areas for enhancement and implementing effective solutions.
Developed in-house commissioning test capabilities, streamlining processes and reducing dependency on external resources.
Defined specifications for automation and protection systems of all power plants for upgrade, ensuring compatibility and seamless integration.
Conducted Job Hazard Analysis for critical tests and work undertaken by office, mitigating potential risks and ensuring safe working environment.
Provided consultancy services for root cause analysis of problems faced by hydro power plants and industries, identifying underlying issues and recommending effective solutions.
Determined budget, manpower, schedule, and material needed to successfully execute projects.
Developed, prepared and reviewed reports and studies to identify and recommend engineering solutions.
Managed maintenance of 4 generators, 4 transformers, and their auxiliaries, ensuring their optimal performance and adherence to safety standards.
Conducted regular inspections, troubleshooting, and maintenance of control and protection equipment, ensuring their efficient operation and reliability.
Coordinated and executed annual maintenance activities for electrical equipment under Electrical Maintenance Unit, guaranteeing uninterrupted power supply and reducing risk of failures.
Collaborated with cross-functional teams, including technicians and contractors, to effectively resolve maintenance issues and implement necessary repairs or upgrades.
Developed and implemented preventive maintenance programs to enhance longevity and reliability of electrical equipment.
Monitored equipment performance and implemented necessary upgrades or repairs to optimize operational efficiency.
Conducted inspections and audits to ensure compliance with safety protocols and regulatory standards.
Prepared comprehensive reports documenting maintenance activities, equipment performance, and identified issues, providing valuable insights for decision-making and future planning.
Adhered to timelines to meet quality assurance targets.
Determined budget, manpower, schedule, and material needed to successfully execute projects.